Following requalification, each cylinder shall be plainly and permanently marked in accordance with CSA B339-14 standard.
The CPA reminds members that the markings shall be arranged horizontally (A B C D E), where:
A = month of requalification (two digits), followed by a space
B = requalifier’s or, where applicable, independent inspector’s registered mark (indicated by XY in
Clause 24.6.3.2), followed by a space
C = year of requalification (last two digits only)
D = procedure symbol (Δ, ★, ♦, , E, R, RB, RH, S, FS or VE), followed by a space
E = repairer’s (if different from requalifier), rebuilder’s, or reheat treater’s registered mark (indicated by
WZ — see Clause 24.6.3.2 of CSA B339-14).